  • TGV307.jpg

TGV307


The TGV307 is a multifunctional, thermally actuated temperature-control valve with on/off switching. It requires no external power supply and is available in a wide range of models, making it particularly suitable for gas heaters, convection air heaters, storage water heaters, wall-mounted heating boilers, commercial gas appliances, and other gas-fired equipment that demands precise temperature control.
Image Name

Customer Service Hotline:


Category:

燃气阀


  • 产品详情
    • Commodity name: TGV307

    The TGV307 is a multifunctional, thermally actuated temperature-control valve with on/off switching. It requires no external power supply and is available in a wide range of models, making it particularly suitable for gas heaters, convection air heaters, storage water heaters, wall-mounted heating boilers, commercial gas appliances, and other gas-fired equipment that demands precise temperature control.

     

    1
     

    Function

    The TGV307 is a multifunctional, thermally actuated temperature-control valve with on/off switching. It requires no external power supply and is available in a wide range of models, making it particularly suitable for gas heaters, convection air heaters, storage water heaters, wall-mounted heating boilers, commercial gas appliances, and other gas-fired equipment that demands precise temperature control.

     

    Technical Specifications

    • Gas connection: G3/8"
    • Gas types: Classes I, II, and III
    • Maximum gas inlet pressure: 50 mbar
    • Outlet pressure adjustment range: 3–18 mbar
    • Operating ambient temperature range: 0~80°C
    • Regulator (optional): Class C
    • Flame inspection device:.
    Ignition time: < 10 seconds Shutdown time: < 60 seconds
    Service life: 10,000
    • Manual flameout device: Service life: 10,000

     

    Key Features

    • The main control knob has OFF, pilot flame, and temperature adjustment (MS) positions.
    • Flame-sensing thermocouple assembly with a flame-out re-start prevention feature (GM)
    • Maximum output air volume adjustment (RQ), or
    • Output pressure regulator (PR)
    • Minimum (bypass) air flow regulation
    • Thermal thermostat (TH) with switching function
    • Pilot flame outlet (RQ) with a preset gas flow regulator
    • Air inlet and pilot flame filter (FL)
    • Pressure monitoring ports for the inlet and outlet
    • Main inlet and outlet ports located on both sides of the valve or at the valve base
    • The main tracheal interface is a threaded tube or a conical tube.

     

    Working Principle Diagram

    1

     

    Installation dimensions (mm)

    1

    The most at range (℃) 8~33 13~31 13~38 13~43 13~48 21~46 30~100 40~72 40~90
    Thermostat diameter 8 8 8 8 8 8 5 8 8
    Thermostat length 125 155 120 155 98 120 122 90 90

     

    Temperature Adjustment Specifications

    The adjustment specifications for the switch-function-modulated thermostat are shown in the figures and tables below.

     

    The regulation range

    1
      a b c
    8~33°C 3 3 2
    13~31°C 2 2 2
    13~38℃ 3 3 2
    13~43°C 3 3 3
    13~48℃ 4 4 3
    21~46℃ 3 3 2
    30~100℃ 9 9 5
    40~72℃ 5 5 3
    40~90℃ 5 5 3

    Customizable based on customer requirements.

     
    Gas flow
    1
    Gas families Q Delta P
    1st (d=0.45) 3.0 m³/h 5m bar
    2nd (d=0.55) 2.7 m³/h 5m bar
    3rd (d=1.55) 1.6 m³/h 5m bar

    The air flow rate Q (at 15°C and 1013.25 mbar) is a function of the inlet–outlet pressure difference ΔP, with the switch set to 7 and the temperature sensor probe in a cooled state.

     

    1
    Curve No. Gas type Inlet pressure range
    Nominal Max. Min.
    1 H 18 23 15
    2 H 20 25 18
    L 20 25 18
    3 L 25 30 20

    The gas flow rate Q (at 15°C and 1013.25 mbar) is defined by EN 88 as a function of the outlet pressure Pu, with the switch set to position 7 and the temperature sensor probe in a cooled state.

    Keywords:
    • 燃气阀